What is Atomic Absorption Spectrophotometer?
Atomic absorption spectrometer(also known as atomic absorption spectrophotometer), analyzes metal elements according to the effect of atomic vapor in the ground state of substances on the absorption of characteristic radiation. It can determine trace or trace elements sensitively and reliably.
Atomic absorption spectrophotometer generally consists of four major parts:light source, sample atomizer(Flame atomizer /graphite furnace atomizer), monochromator and data processing system (including photoelectric converter and corresponding detection device).
What elements can be detected by atomic absorption spectrometer and detection method?
1.Atomic absorption flame method: atomic absorption flame method (air-acetylene) can detect PPM grade.
lithium (Li), sodium (Na), potassium (K), rubidium (Rb), cesium (Cs), magnesium (Mg), calcium (Ca), strontium (Sr), barium (Ba), chromium (Cr), manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), rhodium (Rh), palladium (Pb), platinum (Pt), gold (Au), copper (Cu), silver (Ag), zinc (z η), Germanium (Ge), cadmium (d), indium (n), gallium (Ga), lead (Pb), arsenic (As), bismuth (B), selenium (Se), antimony (Sb), ruthenium (Ru), etc.
2.Atomic absorption hydride method:Atomic absorption hydride method can detect trace elements with low melting point (PPb level).
Determination: arsenic (As), selenium (se), antimony (Sb), bismuth (Bi), lead (Pb), tin (Sn), tellurium (Te), germanium (Ge), mercury (Hg), etc.
3.Atomic absorption graphite furnace method:The element detected by atomic absorption graphite furnace method has less sample injection and high sensitivity (PPb level).
Silver (Ag), aluminum (A), arsenic (As), gold (Au), barium (Ba), beryllium (Be), bismuth (B), calcium (Ca), cadmium (Cd), cerium (Ce), cobalt (Co), cesium (Cs), copper (Cu), dysprosium (Dy), erbium (Er), europium (Eu), iron (Fe), gallium (Ga), holmium (Ho), indium (hn), potassium (K), lanthanum (La), lithium (Li), magnesium (Mg), manganese (Mn), molybdenum (Mo), sodium (Na), nickel (Ni), platinum (Pt), osmium (Os), lead (Pb), palladium (Pd), praseodymium (Pr), hafnium (H), rubidium (Rb), rhodium (Ph), ruthenium (Ru), antimony (Sb), scandium (Sc), selenium (Se), samarium (Sm), tin (Sn), zirconium (zr), tellurium (Te), titanium (T), alum (V), zinc (Zn), silicon (si), etc
Features:
- Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peakheight and area, auto zero adjusting, deuterium lamp background correction,multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
- Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
- Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
- High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
- High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.
- Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys,anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
- Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
- Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame.
- Optional accessories: graphite furnace system,Hydride generator,Hollow cathode lamp,Graphite tubes,PC Software ,Recirculating cooling water system,Technical Specification.
Specifications:
Model No. | AA320N |
Optical System | Czerny-Turner system |
Grating | 1800lines/nm |
Wavelength range | 190-900nm |
Wavelength accuracy | ≤±0.5nm |
Wavelength repeatability | ≤0.3nm (single direction) |
Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base line stability | ±0.004Abs/30min |
Characteristic concentration of copper | ≤ 0.04μg/ml/1% |
Detection limit of copper | ≤0.008μg/ml |
Background calibration ability | Greater than 30 times |
Lamp turret | 4-lamp turret |
Burner head | 100mm titanium burner |
Atomizer | high efficiency glass atomizer |
Atomizer chamber | Explosion-proof premixing |
Output | RS232,Printer (Optional) |
Power supply | AC220V±22V,50Hz±1Hz,200W |
Dimension | 1250mmx795mmx765mm/160kg (Main instrument)
545mmx445mmx1385mm/65kg ( Accessories ) |
Standard Accessories | 10cm Titanium burner,Cu lamp,air compressor, |
Optional Accessories | graphite furnace system,Hydride generator,Hollow cathode lamp,Graphite tubes,Software,Recirculating cooling water system |