Portable Multiparameter PH meter/ Conductivity meter/DO meter
Features:
- Large LCD screen with controllable white backlight.
- Built-in microprocessor chip has Intelligent functions such as auto calibration, ATC, data storage, function settings, auto diagnosis, auto power off, and undervoltage prompt, etc.
PH Mode:
Auto recognition of 25 buffers with three kinds of options: Europe & USA, NIST and China. Support 1, 2, 3 point calibration.
Conductivity Mode:
Adopt advanced conductivity measurement technology, with conductivity electrode (K=1), it can meet measuring accuracy requirement for range of 0.5μS/cm ~ 200mS/cm.
Can switch among conductivity, TDS, salinity and resistivity. Multinomial calculation for TDS and salinity to ensure the conversion precision of the full scale.
Auto recognition of 8 conductivity standard solution with 2 kinds of options: Europe & USA, and China.
DO Mode:
It has functions of ATC, auto salinity compensation and manual pressure compensation.
Polarographic DO electrode, short polarization time (3-5 mintues).
Specifications:
Model | P611 | P612 | P613 | P614 | P615 | P616 | ||
Meters function | PH/MV | ● | ● | ● | ||||
Cond./TDS/Sal./Res | ● | ● | ● | |||||
DO | ● | ● | ● | |||||
Temp. | ● | ● | ● | ● | ● | ● | ||
PH | Measuring range | (-2.00~19.99)pH | ● | ● | ● | |||
Resolution | 0.1/0.01 pH | ● | ● | ● | ||||
Accuracy | Meter:±0.01pH; Overall: ±0.02pH | ● | ● | ● | ||||
Input impendance | ≥1×1012 Ω | ● | ● | ● | ||||
Stability | ±0.01 pH/3h | ● | ● | ● | ||||
Temp. compensation | (0~100)℃ (Auto/manual) | ● | ● | ● | ||||
MV | Measuring range | ±1999.9mV | ● | ● | ● | |||
Resolution | 1mV | ● | ● | ● | ||||
Accuracy | ±0.1% FS | ● | ● | ● | ||||
Cond. | Measuring range | Conductivity:
(0.00~19.99)μS/cm, (20.0~199.9)μS/cm,(200~1999)S/cm, (2.00~19.99)mS/cm, (20.0~199.9)mS/cm |
● | ● | ● | |||
TDS:(0~100)g/L | ● | ● | ● | |||||
Salinity:(0~100)ppt | ● | ● | ● | |||||
Resistivity:(0~100)MΩ·cm | ● | ● | ● | |||||
Resolution | 0.01/0.1/1μS/cm; 0.01/0.1 mS/cm | ● | ● | ● | ||||
Accuracy | ±1.0% FS, Overall:±1.5% FS | ● | ● | ● | ||||
Temp. compensation | (0~100)℃(Auto/manual) | ● | ● | ● | ||||
Electrode constant | 0.1 / 1 / 10 cm-1 | ● | ● | ● | ||||
DO | Measuring range | (0 ~ 20.00) mg/L(ppm), (0 ~ 200.0)% | ● | ● | ● | |||
Resolution | 0.1/0.01 mg/L(ppm), 1/0.1 % | ● | ● | ● | ||||
Accuracy | Electrode: ±0.10 mg/L, Instrument: ±0.40 mg/L | ● | ● | ● | ||||
Response time | ≤30s (25℃, 90%response) | ● | ● | ● | ||||
Residual current | ≤0.1 mg/L | ● | ● | ● | ||||
Temp. compensation | (0 ~ 45)℃ (auto) | ● | ● | ● | ||||
Salinity compensation | (0 ~ 45) ppt (auto) | ● | ● | |||||
Pressure compensation | (66 ~ 200) kPa (manual) | ● | ● | ● | ||||
Auto calibration | Air saturated by water, water saturated by air | ● | ● | ● | ||||
Electrode type | Polarographic | ● | ● | ● | ||||
Temp | Measuring range | (0 ~ 100)℃ | ● | ● | ● | ● | ● | ● |
Resolution | 0.1℃ | ● | ● | ● | ● | ● | ● | |
Accuracy | 5 ~ 60℃:±0.4℃ Others: ±0.8℃ | ● | ● | ● | ● | ● | ● | |
Other | Data storage | 200 sets | ● | ● | ● | ● | ● | ● |
Power | Two AA batteries (1.5V x2) | ● | ● | ● | ● | ● | ● | |
Ambient Temp. | 5 ~ 35 ℃ | ● | ● | ● | ● | ● | ● | |
Ambient humidity | ≤85% | ● | ● | ● | ● | ● | ● | |
IP grade | IP57 Dustproof and waterproof | ● | ● | ● | ● | ● | ● | |
Shipping size | 460*300*55mm/1Kg | ● | ● | ● | ● | ● | ● |