1.Unique optical design greatly increases the sensitivity in visible range. The outstanding mechanical and optical system plus excellent software ensure measurement accuracy 2.Rapid change of gas flow, grating rotation, slit and hollow cathode lamps 3.Widely used in rare earth analysis, precious metal analysis, environmental protection, water quality inspection, alloy materials, construction materials, medicine and health, colleges and universities for quantitative analysis of elements 4.Prac
What is Atomic Absorption Spectrophotometer?
Atomic absorption spectrometer(also known as atomic absorption spectrophotometer), analyzes metal elements according to the effect of atomic vapor in the ground state of substances on the absorption of characteristic radiation. It can determine trace or trace elements sensitively and reliably.
Atomic absorption spectrophotometer generally consists of four major parts:light source, sample atomizer(Flame atomizer /graphite furnace atomizer), monochromator and data processing system (including photoelectric converter and corresponding detection device).
What elements can be detected by atomic absorption spectrometer and detection method?
1.Atomic absorption flame method: atomic absorption flame method (air-acetylene) can detect PPM grade.
lithium (Li), sodium (Na), potassium (K), rubidium (Rb), cesium (Cs), magnesium (Mg), calcium (Ca), strontium (Sr), barium (Ba), chromium (Cr), manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), rhodium (Rh), palladium (Pb), platinum (Pt), gold (Au), copper (Cu), silver (Ag), zinc (z η), Germanium (Ge), cadmium (d), indium (n), gallium (Ga), lead (Pb), arsenic (As), bismuth (B), selenium (Se), antimony (Sb), ruthenium (Ru), etc.
2.Atomic absorption hydride method:Atomic absorption hydride method can detect trace elements with low melting point (PPb level).
Determination: arsenic (As), selenium (se), antimony (Sb), bismuth (Bi), lead (Pb), tin (Sn), tellurium (Te), germanium (Ge), mercury (Hg), etc.
3.Atomic absorption graphite furnace method:The element detected by atomic absorption graphite furnace method has less sample injection and high sensitivity (PPb level).
Silver (Ag), aluminum (A), arsenic (As), gold (Au), barium (Ba), beryllium (Be), bismuth (B), calcium (Ca), cadmium (Cd), cerium (Ce), cobalt (Co), cesium (Cs), copper (Cu), dysprosium (Dy), erbium (Er), europium (Eu), iron (Fe), gallium (Ga), holmium (Ho), indium (hn), potassium (K), lanthanum (La), lithium (Li), magnesium (Mg), manganese (Mn), molybdenum (Mo), sodium (Na), nickel (Ni), platinum (Pt), osmium (Os), lead (Pb), palladium (Pd), praseodymium (Pr), hafnium (H), rubidium (Rb), rhodium (Ph), ruthenium (Ru), antimony (Sb), scandium (Sc), selenium (Se), samarium (Sm), tin (Sn), zirconium (zr), tellurium (Te), titanium (T), alum (V), zinc (Zn), silicon (si), etc
The instrument has good stability, wide measurement range, low detection limit, high resolution and high sensitivity
Unique optical design greatly increases the sensitivity in visible range. The outstanding mechanical and optical system plus excellent software ensure measurement accuracy
Rapid change of gas flow, grating rotation, slit and hollow cathode lamps
Widely used in rare earth analysis, precious metal analysis, environmental protection, water quality inspection, alloy materials, construction materials, medicine and health, colleges and universities for quantitative analysis of elements
Practical structure, simple operation, easy to master
Fully satisfy the users who require flame analysis only
Optional nitrous oxide is available. It expands measurement range and meets the demands from different areas.
| Item | 5800 |
| Wavelenth Range | 190-900nm |
| Grating | 1800lines/nm |
| Optical System | Czerny-Turner system,integrated optical platform, fully sealed optical system |
| Wavelength Repeatability | ±0.1nm |
| Wavelength Indication Error | Whole range ±0.2nm |
| Resolution | Spectral bandwidth =0.2nm can separate Mn two lines (279.5nm and 279.8nm, valley/peak energy ratio <30% |
| Spectral Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.0nm |
| Static Baseline Drift | ≤0.004ABS/30min(Cu) |
| Lamp Turret | 4-lamp turret(4 lamps can be preheated simultaneously) |
| Burner Head | Air-acetylene burner head(100mm, optional 50mm nitrous oxide-acetylene is available) |
| Atomizer | High-efficiency glass Atomizer |
| Ignition Dynamic Baseline Drift | ≤0.004ABS/30min(Cu) |
Characteristic Concentration (Cu) | ≤0.025μg/ml/1%(Absorbance>0.8ABS) |
| Detection Limit | Cu≤0.008ug/ml |
| Repeatability (Cu) | ≤0.5% |
| Gas Flow Control | Manual |
| Ignition Method | via buttons on the control panel |
| Safety Protection | Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched |
| Background Correction Method | SR and D2, correct 1A background. When background signal =1Abs, correction capability ≥50 times |
| Function expansion | 6 lamp+ 8 lamp +Hydride system |
How to centre the light of Spectrophotometer
replace deuterium lamp and tungsten lamp for Spe